[Contents] [Index] [Help] [Retrace] [Browse <] [Browse >]


NAME
    TR_SETSYSTIME -- Set the system time.

FUNCTION
    Set the system idea of what time it is.  The system starts out
    at time "zero" so it is safe to set it forward to the real
    time.  However, care should be taken when setting the time
    backwards.  System time is generally expected to monotonically
    increasing.

TIMER REQUEST
    io_Message      mn_ReplyPort initialized
    io_Device       preset by timer in OpenDevice
    io_Unit         preset by timer in OpenDevice
    io_Command      TR_GETSYSTIME
    io_Flags        IOF_QUICK permitted
    tr_time         a timeval structure with the current system
                        time

RESULTS
    tr_time         will contain junk

NOTES
    This function may be called from interrupts.

SEE ALSO
    timer.device/TR_GETSYSTIME,
    timer.device/GetSysTime(),

BUGS